The core solar cables of any diameter from 2.5mm2 up to 16mm2 are made in Shanhai,China. The standards of the cable covers single core and dual core. The layers of insulation are distinguished by color for improved and safer handling.
We supply only color-coded cables for safe and easy installation. The red cables are intended for use in positive (+) DC voltage and black cable are used for negative (-) DC voltage.
The cables are suitable for nominal DC voltage 1.5KV (Between conductor to conductor or conductor to earth) solar power systems.
● Halogen Free,Flame-resistant.
● 15 Years of Production Experience In Power Cable.
● TUV Approved & TUV 2PFG 1169/08.2007 PVI-F.
● Double Insulation Suitable for outdoor harsh environments.
● Stable connection & Reducing maintenance cost.
● Free Sample is available.
TUV EN50618 H1Z2Z2-K & IEC62930 Solar cable 1* X mm2 & 2*X mm2 |
||
Conductor | Tinned fine Re copper strands,according to IEC60228.Class5 | |
Insulation | LSZH electron-beam cross-linked Polyolefin copolymer ROHS material, prior color black or as per customer’s request | |
Sheath Jacket | LSZH & UV-resistant electron-beam cross-linked Polyolefin copolymer ROHS material, prior color black or as per customer’s request. | |
Sheath color |
Red/Black | |
Nominal Voltage | UO/U 1.0/1.0 KV (AC) , 1.5/1.5kV (DC) | |
Test voltage | No breakdown at 6.5 kV (AC) 50HZ 5min 20±5°C /15kV(DC) 5min 20±5°C | |
Temperature Rating | Working Temperature —40C 〜+ 90 °C, Max conductor Temperature 125 °C (continuously 20h), Allowable short circuit temperature 200°C in 5 second | |
Fire-resistant Performance | IEC 60332-1:2004 | |
Smoke Emission | IEC61034-1, min 60% luminousness;EN50268-2 | |
Halogen Conten | EN 50525-1:2011, Appendix B | |
Low Fire Load | DIN 51900 | |
Executive Standard | EN 50618:2014 | |
Certification | TUV EN50618 H1Z2Z2-K & IEC62930 |
Low Losses In Every Part Of Your Solar System: The solar off grid or grid-tied system must be carefully designed with a target overall efficiency around 95%. To reach this target, we should not underestimate how important the selection of cables is.
Construction (Nxmm2) |
Finished Cable OD(mm) |
Max DC Resistance at 20 C (Q/KM) |
Current (A) |
Underground installation |
|||
1×2.5 mm2 |
5.05±0.2 |
8.21 |
39 |
1×4 mm2 |
5.55±0.3 |
5.09 |
52 |
1×6 mm2 |
6.15±0.3 |
3.39 |
67 |
1×10 mm2 |
7.4±0.3 |
1.95 |
93 |
1×16 mm2 |
8.72±0.3 |
1.25 |
125 |
2×2.5 mm2 |
5.55±0.3×11.6±0.5 |
8.21 |
39 |
2×4 mm2 |
5.05±0.3×10.5±0.5 |
5.09 |
52 |
2×6 mm2 |
6.15±0.3×12.9±0.6 |
3.39 |
67 |
2×10 mm2 |
7.4±0.3×15.4±0.8 |
1.95 |
93 |
2×16 mm2 |
8.72±0.3×18.1±0.8 |
1.25 |
125 |
JIUKAI CABLE OBTAINS TUV EN50618 H1Z2Z2-K & IEC62930 AND OTHER CERTIFICATIONS.